PV models generated for a facility from tools like PV Syst can be uploaded for energy comparison to actual and expected generation.

Use the “Energy Model” page to preview the currently uploaded model, download the existing model or an empty template, and upload new data.

energy_model.png

Data is uploaded in 8760 format. Click “Download” to get a copy of the CSV template. Fill in data from your 8760 file in the associated columns, and then re-upload.

<aside> 💡 If your 8760 provides energy values in W (watts) or temperatures in F (Fahrenheit), you will need to convert these to values to kW (kilowatts) and C (Celsius) before uploading.

</aside>

<aside> 💡 When saving the file, make sure to preserve the “.CSV” extension - don’t convert to “.XLSX”

</aside>

energy_model_csv.png